• Automation Technology
  • Aviation
  • Medical Engineering
  • Machine Engineering
  • Measurement Engineering
  • Traffic Engineering
  • Green Energy
  • Development
  • AC/DC Universal Input

Product Database

Your Product Choice:

DV1M-SH7R
1W
Medical Application, SIP 7
I/O Isolation: 6000 VDC
Input: ±10%
4,5-5,5/10,8-13,2/21,6-26,4 VDC
Vo: 3,3/5/12/15/±5/±9/±12/±15 VDC
Unregulated,EN60601,2MOOP,Reinforced Insulation

DV64B-MED
6W
Medical Application, DIP 24
I/O Isolation: 6000 VDC
Input: 4:1
9-36/18-72 VDC
Vo: 5/12/±12/±15 VDC
UL62368, EN55032 A, Reinforced Insulation 300VAC

DV6MB4-MED
6W
Medical Application, DIP 24
I/O Isolation: 6000 VDC
Input: 4:1
9-36/18-75 VDC
Vo: 5/12/15/24 VDC
EN60601(MED),Reinforced Insulation,EN55032 A

DV10B18-72-4,2KV
10W
Medical Application, DIP 24
I/O Isolation: 4200 VDC
Input: 8,5-160 VDC
18:1
Vo: 5/12/15/±5/±12/±15 VDC
Reinforce Insulation, EN50155, EN55032 Class A

DV104B-Railway
10W
Railway Application, DIP 24
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 3,3/5/12/15/±5/±12/±15 VDC
EN50155, Efficiency to 88%, SCP/OCP/UVP

DV204X-Railway
20W
Railway Application, "50,8 x 25,4 (mm) / 2""x1"""
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 5/12/15/±12/±15 VDC
EN50155 (Railway), Efficiency to 90%, SCP/OVP/OCP

DV404XL-Railway
40W
Railway Application, "52,0 x 30,5 (mm) / 2""x1,2"""
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 3,3/5/12/15/±12/±15/±24 VDC
EN50155, EN45545-2, Efficiency 91%, SCP/OCP/UVP

DV5012-72Q
50W
Railway Application, Quarter-Brick 57,9 x 36,8 (mm)
I/O Isolation: 3000 VDC
Input: 14-160 VDC
12:1
Vo: 5/12/24/48 VDC
UL62368-1, EN50155, EN45545-2, Efficiency to 89%

DV5010-72QCHAL
50W
Railway Application, 116,8 x 61 x 32 (mm)
I/O Isolation: 3000 VDC
Input: 14-160 VDC

Single: 5/12/24/48 VDC
Screw Terminal, Meet IEC/EN62368-1, EN50155

DV604Q-Railway
60W
Railway Application, Quarter-Brick 57,9 x 36,8 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 5/12/15/24/28/48 VDC
Meet IEC/EN/UL62368-1, EN50155, Efficiency to 92%

DV100Q14-72
100W
Railway Application, Quarter-Brick 57,9 x 36,8 (mm)
I/O Isolation: 3000 VAC
Input: 12-160 VDC
14:1
Vo: 5/12/15/24/28/48 VDC
UL62368(Reinforce Insulation),EN50155, Eff. to 89%

DV100Q4-110
100W
Railway Application, Quarter-Brick 57,9 x 36,8 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 5/12/24/28/48 VDC
Meet IEC/EN/UL62368-1, EN50155, Efficiency to 92%

DV100Q3-110
100W
Railway Application, Quarter-Brick 57,9 x 36,8 (mm)
I/O Isolation: 2250 VDC
Input: 66-160 VDC
3:1
Vo: 3,3/5/12/24 VDC
Meet IEC/EN/UL62368-1, EN50155, Efficiency to 93%

DV100Q3-110-DR
100W
Railway Application, 96 x 40 x 37,8 (mm)
I/O Isolation: 2250 VDC
Input: 66-160 VDC

Single: 5/12/24 VDC
Screw Terminal, EN50155, Meet IEC/EN/UL62368-1

DV100Q3-110-CH
100W
Railway Application, 96 x 40 x 25 (mm)
I/O Isolation: 2250 VDC
Input: 66-160 VDC

Single: 5/12/24 VDC
Screw Terminal, EN50155, Meet IEC/EN/UL62368-1

DV100H3-110
100W
Railway Application, Half-Brick 61 x 57,9 (mm)
I/O Isolation: 3000 VDC
Input: 66-160 VDC
3:1
Vo: 12/15/24/48 VDC
Meet IEC/UL62368-1, EN50155, Efficiency to 89%

DV150Q4-110
150W
Railway Application, Quarter-Brick 57,9 x 36,8 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 5/12/24/28/48 VDC
Meet IEC/UL62368-1, EN50155, Efficiency to 92%

DV150Q4-110-CHAL
150W
Railway Application, 116,8 x 61 x 32 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC

Vo: 3,3/5/12/24/28/48 VDC
Screw Terminal, Meet IEC/EN/UL62368, EN50155

DV150H12-72
150W
Railway Application, Half-Brick 61 x 57,9 (mm)
I/O Isolation: 3000 VAC
Input: 14-160 VDC
12:1
Vo: 5/12/15/24/48 VDC
UL62368(Reinforced Insulation),EN50155, Eff. to 91%

DV150H3-110
150W
Railway Application, Half-Brick 61 x 57,9 (mm)
I/O Isolation: 2250 VDC
Input: 66-160 VDC
3:1
Vo: 5/12/24 VDC
Meet IEC/UL62368-1, EN50155, Efficiency to 92%

DV200H12-72
200W
Railway Application, Half-Brick 61 x 57,9 (mm)
I/O Isolation: 3000 VAC
Input: 14-160 VDC
12:1
Vo: 12/24/28/48 VDC
UL62368(Reinforced Insulation),EN50155, Eff. to 91%

DV200H4-110
200W
Railway Application, Half-Brick 61 x 57,9 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 5/12/24/28/48 VDC
Meet IEC/UL62368-1, EN50155, Efficiency to 91%

DV300H4-110
300W
Railway Application, Half-Brick 61 x 57,9 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC
4:1
Vo: 3,3/5/12/24/28/48 VDC
Meet IEC/UL62368-1, EN50155, Efficiency to 91%

DV300H4-110-CHAL
300W
Railway Application, 165 x 76,2 x 38,5 (mm)
I/O Isolation: 3000 VDC
Input: 43-160 VDC

Vo: 3,3/5/12/24/28/48 VDC
Screw Terminal, Meet IEC/EN62368, EN50155

DV600F4-110
600W
Railway Application, Full-Brick 116,8 x 61 (mm)
I/O Isolation: 2250 VDC
Input: 43-160 VDC
4:1
Vo: 12/24/28/48 VDC
Meet IEC/UL62368-1, EN50155, Efficiency to 88%

DV600F4-110-CHAL
600W
Railway Application, 240 x 110 x 42 (mm)
I/O Isolation: 2250 VDC
Input: 43-160 VDC

Vo: 12/24/28/48 VDC
Screw Terminal, Meet IEC/EN62368-1, EN50155

Back to Overview