• Automation Technology
  • Aviation
  • Medical Engineering
  • Machine Engineering
  • Measurement Engineering
  • Traffic Engineering
  • Green Energy
  • Development
  • AC/DC Universal Input

Product Database

Your Product Choice:

DV1M-SH7R
1W
Medical Application, SIP 7
I/O Isolation: 6,0 KVDC
Input: ±10%
Vin: 5/12/24 VDC
Vo: 3,3/5/12/15/±5/±9/±12/±15 VDC unger./unreg.
UL60601-1, 2xMOOP/Reinforced Insulation
DV2M-SH7R
2W
Medical Application, SIP 7
I/O Isolation: 6,0 KVDC
Input: ±10%
Vin: 5/12/24 VDC
Vo: 5/12/15/±5/±9/±12/±15 VDC unger./unreg.
UL60601-1, 2xMOOP/Reinforced Insulation
DVE32B-MED
3W
Medical Application, DIP 24
I/O Isolation: 5,6 KVDC
Input: 2:1
Vin: 4,5-9/9-18/18-36/36-72 VDC
Vo: 3,3/5/12/15/±5/±12/±15 VDC
UL60601-1, MOOP/Reinforced Insulation 300VAC
DVE34B-MED
3W
Medical Application, DIP 24
I/O Isolation: 5,6 KVDC
Input: 4:1
Vin: 9-40/18-74 VDC
Vo: 3,3/5/12/15/±5/±12/±15 VDC
UL60601-1, MOOP/Reinforced Insulation 300VAC
DVE62B-MED
6W
Medical Application, DIP 24
I/O Isolation: 5,6 KVDC
Input: 2:1
Vin: 9-18/18-36/36-72 VDC
Vo: 5/12/15/±5/±12/±15 VDC
UL60601-1, MOOP/Reinforced Insulation 300VAC
DV64B-MED
6W
Medical Application, DIP 24
I/O Isolation: 6,0 KVDC
Input: 4:1
Vin: 9-36/18-72 VDC
Vo: 5/12/±12/±15 VDC
UL60601-1/Reinforced Insulation 300VAC
DV104B-Railway
10W
Railway Application, DIP 24
I/O Isolation: 3,0 KVDC
Input: 43-160 VDC

Vo: 12/15/±5/±12/±15 VDC
EN50155/UL60950-1
DV204X-Railway
20W
Railway Application, 50,8 x 25,4 mm²
I/O Isolation: 2,25 KVDC
Input: 43-160 VDC

Vo: 5/12/15/±12/±15 VDC
UL60950-1 Approved, EN50155
DV404XL-Railway
40W
Railway Application, 52,0 x 30,5 mm²
I/O Isolation: 2,25 KVDC
Input: 43-160 VDC

Vo: 3,3/5/12/15/±12/±15/±24 VDC
UL60950-1 Approved, EN50155
DV5012-72Q
50W
Railway Application, Quarter-Brick 57,9 x 36,8 mm²
I/O Isolation: 3,0 KVDC
Input: 14-160 VDC

Vo: 5/12/24/48 VDC
UL60950-1, EN50155, Temp.Geh./Temp.Case +100°C
DV5010-72QCHAL
50W
Railway Application, 116,8 x 61 x 32 mm³
I/O Isolation: 3,0 KVDC
Input: 16,8-160 VDC

Single: 5/12/24/48 VDC
Open frame/Metallgehäuse/Metal Case, EN50155
DV604Q-Railway
60W
Railway Application, Quarter-Brick 57,9 x 36,8 mm²
I/O Isolation: 2,25 KVDC
Input: 43-160 VDC

Vo: 5/12/15/24/28/48 VDC
UL60950-1 Approved, EN50155, Temp. bis/to +100°C
DV1003Q-Railway
100W
Railway Application, Quarter-Brick 57,9 x 36,8 mm²
I/O Isolation: 2,25 KVDC
Input: 66-160 VDC

Vo: 3,3/5/12/24 VDC
UL60950-1 Approved, EN50155, Temp. bis/to +100°C
DV1003H-Railway
100W
Railway Application, Half-Brick 61 x 57,9 mm²
I/O Isolation: 3,0 KVDC
Input: 66-160 VDC

Vo: 12/15/24/48 VDC
UL60950-1, EN50155, Temp.Geh./Temp.Case +100°C
DV1504Q-Railway
150W
Railway Application, Quarter-Brick 57,9 x 36,8 mm²
I/O Isolation: 3,0 KVDC
Input: 43-160 VDC

Vo: 5/12/24/28/48 VDC
UL60950-1 Approved, EN50155, Temp. bis/to +105°C
DV1504-110QCHAL
150W
Railway Application, 116,8 x 61 x 32 mm³
I/O Isolation: 3,0 KVDC
Input: 43-160 VDC

Single: 5/12/24/28/48 VDC
Open frame/Metallgehäuse/Metal Case, EN50155
DV1503H-Railway
150W
Railway Application, Half-Brick 61 x 57,9 mm²
I/O Isolation: 2,25 KVDC
Input: 66-160 VDC

Vo: 5/12/24 VDC
UL60950-1 Approved, EN50155, Temp. bis/to +105°C
DV2003F-Railway
200W
Railway Application, Full-Brick 116,8 x 61 mm²
I/O Isolation: 2,25 KVDC
Input: 66-160 VDC

Vo: 12/15/24/48 VDC
UL60950-1, EN50155, Temp.Geh./Temp.Case +100°C
DV3004H-Railway
300W
Railway Application, Half-Brick 61 x 57,9 mm²
I/O Isolation: 2,25 KVDC
Input: 43-160 VDC

Vo: 5/12/24/28/48 VDC
UL60950-1, EN50155, Temp.Geh./Temp.Case +100°C
DV3004-110HCHAL
300W
Railway Application, 165 x 76,2 x 40 mm³
I/O Isolation: 3,0 KVDC
Input: 43-160 VDC

Single: 5/12/24/28/48 VDC
Open frame/Metallgehäuse/Metal Case, EN50155

Back to Overview